Warning the servicing instructions are for use by qualified. The amplitude accuracy specifications are guaranteed at 23c 3c or 73f 5f. Able to measure current from 5 ma to 30a no need to open the circuit, no need electric contact for ac and dc current can be used with all dmm who including acdc mv fu. Acdc current probes cp1 series h typical applications o light industrial and residential electrical installation testing. N7026a 150 mhz acdc high sensitivity current probes user. Tcp0030a is a highperformance, easytouse ac dc current probe designed for use and direct connection to oscilloscopes with the tekvpi probe interface. Probes are circuits composed of distributed resistance, inductance, and capacitance r, l, and c. Warning the servicing instructions are for use by qualified personnelonly. Tcp300400 series acdc current probes zzz instruction manual xx revision a this document applies for. These three probes provide current measurement capabilities of. Tcp0020 datasheet24 pages etc2 acdc current probes. Acdc current probes cp3 series typical applications o light industrial and residential electrical installation testing o leakage current measurements o process control for 4 20ma current. Meets todays acdc current measurement applications the tcpa300 amplifier, when used with tcp312a, tcp305a, or tcp303 probes, provides a wide range of current measurement capability and. Acdc currentprobes tcp0020 tcp2020 tcp202a ordering information tcp0020 acdc current probe.
Fluke i410i1010 acdc current clamp instruction sheet. Based on a combination of hall effect and transformer. Free shipping on many items browse your favorite brands. Pdi ca60 handheld 60 amp acdc current clamp probe, red. Key performance specifications dc to 20 mhz bandwidth 150 arms maximum current capability 500 a peak pulse current capability. Ct235a, ct237a acdc current probes user manual english.
Fluke i2000 flex ac current clamp the i2000 is an ac current probe utilizing the rogowski principle. Every battery is designed to produce only one voltage level, and that voltage of direct current cannot travel very far until it begins to lose energy. Hioki acdc clamp sensors are bestinclass current sensors for use with power meters, memory hicorders and high performance oscilloscopes. Current probes are designed to sense the strength of the electromagnetic field around the conductor and convert it to a corresponding voltage for measurement by an oscilloscope. The acp and acp 1005 are ac current probes utilising rogowski principle. The gmw cpco dcac clampon current probe enables electrically isolated monitoring of high electric currents without disconnection of the primary current conductor. There are ac and acdc versions of clampon current probes and there are various current conversion factors available.
Acdc current probes tcp0020 tcp2020 tcp202aordering informationtcp0020acdc current probe. Select ac millivolts to measure alternating current and dc millivolts for direct current. It is ideal for acquiring high transient time signals such as those found in motor controllers, in switching power supplies, and in current amplifiers driving inductive loads. Current clamps are designed with jaws that can be opened, placed around the. Meets todays ac dc current measurement applications the tcpa300 amplifier, when used with tcp312a, tcp305a, or tcp303 probes, provides a wide range of current measurement capability and spans the gap between lowlevel milliamp measurements to very high current levels. Able to measure current from 5 ma to 30a no need to open the circuit, no need electric contact for ac and dc current can be used with all dmm who including ac dc mv fu. The ct235a and the ct237a current probes have been designed for use with digital multimeters, recorders and other suitable equipment for accurate nonintrusive measurement of ac, dc and. Limited warranty and limitation of liability your amprobe product will be free from defects in material and workmanship for 1 year from the date.
Acdc current probes cp1 series h typical applications o light industrial and residential electrical installation testing o battery charging systems o analysis of switching waveforms in inverters, switch mode power supplies and industrial controls. The tcp0020 and tcp2020 provide a maximum 20 a rms measurement range, while the tcp202a. Ac dc current probes k series k series the k series is a new product range with exceptional measurement capabilities. Shop fluke current clamps and current probes fluke. Another difference between ac and dc involves the amount of energy that each one can carry. Compatible with any oscilloscope with high impedance bnc input, the new n2783 series current probe offers accurate and reliable solution for measuring ac and dc currents. Using a hybrid technology that includes a hall effect sensor and an ac current transformer, the probe provides accurate measurement of dc or ac currents up to 30 arms continuous. Key performance specifications dc to 20 mhz 18008339200. The i30s current clamp is based on hall effect technology for use in measurement of both dc and ac. This item pdi ca60 handheld 60 amp acdc current clamp probe, red bside acm91 digital clamp meter 1ma acdc current true rms autoranging 6000 counts meter hz temperature capacitance.
This item pdi ca60 handheld 60 amp ac dc current clamp probe, red bside acm91 digital clamp meter 1ma ac dc current true rms autoranging 6000 counts meter hz temperature capacitance live check valert low impedance voltage tester. Acdc current probe tcp0150 datasheet the tcp0150 is a high performance and easytouse 150 a acdc current probe designed for use and direct connection to the tekvpi probe interface. The ct6845 is a highprecision 500 a ac dc current probe that features a wide operating temperature range and large jaw diameter, making them ideal for evaluating the operational integrity of devices that are subject to extreme temperature ranges. Current clamps offer a safe, costeffective, simple and accurate way to take current measurements. Datasheettcp0020, tcp2020, tcp202athe tcp0020, tcp2020, and tcp202a are a family of highperformance,easytouse acdc current probes designed for use with a varietyof oscilloscopes. Ac voltage from a generator in a power plant can be bumped up or down in strength by another mechanism. These ac dc current probes provide sufficient performance to support 50 mhz measurement system bandwidth. For more information, refer to the tcpa300400 ampli.
The tcp0150 is a high performance and easytouse 150 a acdc current probe designed for use and direct connection to the tekvpi probe interface. Ct235a and ct237a acdc current probes product manual. Acdc oscilloscope clamp on current probes new family of performance oscilloscope current probes. Clampon current probes or current clamps enable you to measure currents without breaking the electrical circuit. Get the best deals on current probes when you shop the largest online selection at. The probes provide a 1v full scale ac output proportional to the. The flexible probe allows current measurements on conductors that are hard to reach. The tcp0020 and tcp2020 provide a maximum 20 a rms measurement range, while the. There are ac and ac dc versions of clampon current probes and there are various current conversion factors available. To avoid personalinjury,do not perform any servicing unless you are qualified to do so. With pdf like sharing, space and time barriers are removed between team members, enhanced learning achieved between students and professors. Ac current 200a dc current 200a accurate dcac current probe 10madc, 1maac high resolution one touch zero for dca adjustment. The tcp202 current probe figure 1 is a 50 mhz current probe for use with tektronix oscilloscopes that have the tekprobe interface. How to select the right current probe application note.
N7026a 150 mhz acdc high sensitivity current probes users guide. Warning the servicing instructions are for use by quali. Every battery is designed to produce only one voltage level, and that voltage of direct current. Ac current 200a dc current 200a accurate dc ac current probe 10madc, 1maac high resolution one touch zero for dca adjustment. They are built to the latest safety and performance standards, including the ce mark. Apr 16, 2020 another difference between ac and dc involves the amount of energy that each one can carry. Current probes are designed to sense the strength of the electromagnetic field.
Specifications and appearance subject to change without notice. Select the required current range 20 amp or 200 amp for the ct237a. Teledyne lecroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. The ct6845 is a highprecision 500 a acdc current probe that features a wide operating temperature range and large jaw diameter, making them ideal for evaluating the operational integrity of devices that are subject to extreme temperature ranges. The tcp2020 is designed for use with any instrument with bncinputs and 100 k. They indicate the shape and amplitude of the current measured in the form of a voltage. Tcp202 15 ampere acdc current probe instruction manual. Based on a combination of hall effect and transformer technology, teledyne lecroy current probes are ideal for making accurate ac, dc, and impulse current measurements. Hioki ac dc clamp sensors are bestinclass current sensors for use with power meters, memory hicorders and high performance oscilloscopes. N7026a 150 mhz acdc high sensitivity current probes users guide introduction the n7026a is a wideband, dc to 150 mhz, clampon active current probe. Our range of current clamps can be used with picoscope oscilloscopes and picolog data loggers, as well all major brands of oscilloscopes and multimeters. They are built to the latest safety and performance. The ct6846 is a highprecision a acdc current probe that features a wide operating temperature range and large jaw diameter, making them ideal for evaluating the operational integrity of devices that are subject to extreme temperature ranges.
17 1304 701 1549 640 1541 1491 1111 698 1406 1516 404 8 1258 1048 666 97 827 514 1623 1456 107 63 42 87 828 1259 619 941 144 194 455 150 546 253